$9,147.00 $13,446.09

The nXe Series NXE8004 4-Channel 800W Power Amplifier with Programmable Outputs & Ethernet Control from Ashly is a Class-D switching amplifier combined with a switch mode power supply. This amplifier meets the requirements of demanding live sound and fixed installation sound systems in stadiums, arenas, performance venues, worship spaces, and convention centers.

The rear panel has DIP switches for programming each channel output for either High-Z or Low-Z operation. This amplifier can be connected to a network with Ethernet control and features serial data control, aux preamp outputs, instant standby mode, preset recall, fault condition logic outputs, and optional network audio and digital audio capability, all controlled using the Protea Software Suite (not included).

General
Voltage GainSelectable at 26, 32, or 38 dB, and 1.4 V
Damping Factor>250 (8 Ω load <1 kHz)
FilterInput High Pass Filter: 80 Hz 2nd order
Distortion<0.5% SMPTE, typical
<0.5% THD-N, typical (8 Ω, 10 dB below rated power, 20 Hz to 20 kHz)
Channel Separation-75 dB (dB from full output, 1 kHz)
Signal / Noise20 Hz to 20 kHz, un-weighted
>108 dB
Frequency Response20 Hz to 20 kHz, ±0.05 dB
ConnectorBalanced Input Connector: Euroblock 3.5 mm, 1/4" TRS and XLR combo jack
Input Impedance10 kΩ
Maximum Input Level21 dBu
Speaker OutputConnector: Neutrik speakON
NetworkControl Network: Compatible with standard 100 MB Ethernet
AUX OutputsConnector: Balanced Euroblock 3.5 mm
Maximum Output Level: 21 dBu
Contact ClosureRemote Standby: Euroblock 3.5 mm, close contact to GND for standby mode
Preset Recall: Euroblock 3.5 mm, close contact to GND for preset 1-4 recall
DataData Connection: Euroblock 3.5 mm - Gnd, 18 V, in, out
OutputsFault Condition Logic Outputs: 4 x 3.5 mm Euroblock
Level ControlRemote DC: 4 x 3.5 mm Euroblock - Gnd, CV, V+ per input
AttenuationFront panel, software, offset link group, and remote per channel
Fully off = mute
Protection CircuitsInrush current limitation, temperature monitoring, output over-power protection, and mains fuses
CoolingContinuously variable temperature controlled axial fans
EnvironmentalNon-condensing 32 to 113°F (0 to 45°C)
Power Requirements
PowerAt 50 Hz
Nominal (Automatic Sensing SMPS): 120 VAC
Operating Range: 70 to 135 VAC
Minimum Power-Up: 85 VAC

At 60 Hz
Nominal (Automatic Sensing SMPS): 240 VAC
Operating Range: 140 to 270 VAC
Minimum Power-Up: 170 VAC
ConnectorPower Cable Connector: 20 A powerCON
Maximum Output PowerPer Channel, Low-Z Output, All Channels Driven
2/4/8 Ω: 800 W
OutputLow Z Output, Bridge Mode, All Channels Driven: 1600 W (4/8 Ω)
70V, 100V Output, All Channels Driven: 800 W (70/100 V (per channel)
Power DrawSleep Mode: < 1 W
Standby Mode: 40 W
Idle (No Signal): 70 W
Current DrawFor 120 VAC
Sleep Mode: 0.1 A
Standby Mode: 0.70 A
Idle (No Signal): 1.30 A

For 240 VAC
Sleep Mode: 0.05 A
Standby Mode: 0.35 A
Idle (No Signal): 0.65 A

Maximum, All Channels Driven, Typical Input
1/8 Max Power @ 2 Ω): 8.8 A for 120 VAC, 4.4 A for 240 VAC

DissipationThermal Dissipation: Sleep Mode: <3.4 BTU/hr
Standby Mode: 136 BTU/hr
Idle (no signal): 238 BTU/hr
Typical (1 / 8 Max Power @ 2 Ω): 970 BTU/hr
LED IndicatorsFront Panel LED Indicators

White: Power Switch: On, off, standby (flashing)

Red LED:
Clip / Mute Per Channel: Clip @ 1 dB below full output / mute
Protect: On (fault condition or shut down), Off

Green LED:
Signal Per Channel: -18 dBu, below rated output
Bridge Per Channel Pair: On, off
Com: On, for Ethernet data or device ID
Current Per Channel: Proportional to output

Yellow LED:
Temperature Per Channel: On dim at 90% maximum operating temperature, full bright + protect at 100%
Sleep: On, amplifier is asleep from audio inactivity
Disable: On, power switch & front panel attenuators are disabled

Dimensions19.0 x 3.5 x 16.8" (48.3 x 8.9 x 42.8 cm)
Weight32.4 lb (14.8 kg)
Packaging Info
Package Weight32.5 lb

4-Channel high-output amplifier with programmable output on each channel (High-Z or Low-Z, selected via rear panel DIP switches)

Power-saving, Energy Management System with automatic <1W sleep-mode (defeatable)

Front panel power switch and level controls (can be disabled for security)

Rear panel DIP switches per channel for selection of high pass filter, limiter, input gain, and High-Z or Low-Z speaker output configuration

Remote DC level control on each input channel

Switch mode power supply automatically detects 120 or 240VAC operation

Extensive protection circuitry and continuously variable cooling fans

Multiple independent internal power supplies provide increased channel separation and reliability

Ethernet port for control and monitoring of amplifier functions, with front panel COM activity LED

Serial data port for use with Ashly remote control devices, or optional RS-232 converter for third party controllers (not included)

Protea software allows to remotely disable all front panel controls, including the on/ off switch, for a tamper-proof installation

Real-time clock with event scheduler

Instant standby mode that can be triggered by contact closure, software control, or event scheduler for reduced power consumption

Programmable power-on delay

Preset recall via contact closure, software control, remote control, or event scheduler

Aux preamp outputs, and fault condition logic outputs

Optional Cobranet or Dante network audio and AES3 digital audio input with pass-through

Neutrik Combo XLR - 1/4" TRS jack plus Euroblock input connectors

Neutrik speakON twist locking loudspeaker connectors for security, safety, and reliability

Neutrik powerCON detachable AC mains connector

Made in USA

Related Questions and Answers

Q: 1. How loud do the fans get, do you hear them?

A: The Yamaha PX8 is made primarily for live sound reinforcement. In that environment, you would not hear the cooling fans in the PX8 amplifier.

Q: 2. how do you rack mount this amp?

A: Use a rack shelf.

Q: 3. Can you connect this to home audio receiver?

A: Not from the speaker outputs on the home audio receiver. Only if it has pre-outs available for that. A lot of models only have pre-outs for use with powered subwoofers.

Q: 4. how to bridge 4 speakers at 8 ohms?

A: I'm afraid I had to call the manufacturer in Canada - Alas now days weno longer have the luxury of manuals inside the box with the amp .I also have 4 speakers bridged at 8ohms but cannot remember theconfiguration with the connecting blocks.Once you get this set up you will be well pleased - This Is A terrific power amp - 10 stars PC LA

Q: 5. Is there an aux cord? or would I need the usb cord and then an adapter to the phone?

A: The CDi2000 is designed for commercial installations. The inputs on this power amp are 3pin phoenix connectors. If you are looking to connect audio devices to the amplifier, it is recommended to do so with a mixer which can be wired with adapters to the phoenix connector inputs of the amplifier.

Q: 6. what kind of speakers to use with these?

A: This amplifier is designed for commercial installation systems that offer 70 or 100 volt taps.

Q: 7. Is this amplifier CE certified?

A: The Ashly TRA-4150 is Not only CE certified but Safety/Compliance: TUV, FCC, and RoHS.

Q: 8. can i install a separate volume control in the wall in another room ? if so is there a spec?

A: You can as long as it's able to handle the wattage. In this case it would be 100w per channel.

Q: 9. This unit says it has 8-channel AES inputs. Does it also have 8-channel AES outputs?

A: AES3 digital audio output is available as a 4- or 8-channel option for the Ashly ne8800A Network Enabled Digital Signal Processor. The AES3 outputs are pass-through only (no DSP).

Q: 10. Would this amp work with PVI 10 (Peavey) speakers (100 watts) along a Pioneer ddj controller? If is does...What accessories do I need in order to connect everything?

A: The Peavey PVI 10 speakers handle 100W peak power (not constant power) and 50W program power, so they handle less power than the amplifier puts out. You would need to be very careful to avoid damaging the speakers with too much power from the amp and keep the volume level low or use speakers that can handle more power like Mackie C200 Passive 10" 2-Way Loudspeaker (B&H # MAC200). The Peavey speakers have 1/4" inputs and the Pyle amp has SpeakOn output connectors so you could use cables like the Hosa Technology SKT-200 Series Speakon to 1/4" Male Phone Speaker Cable (12 Gauge) - 50' (B&H # HOSKT250Q). Please contact us if you would like further assistance with your setup. You may be better off using powered speakers instead of the amp and passive speakers.

There are no reviews for this product.

Write a review

Note: HTML is not translated!
    Bad           Good
Captcha

Top Bestselling Products

Art Sla-1 100w 2-channel Amplifier

$899.97 $1,250.96

Radial Engineering Jd 6 Six-channel Direct Box

$3,299.97 $4,289.96

Muxlab Dante 2-channel 240w Power Amplifier

$2,693.85 $3,367.31

Marantz Mm8077 7-channel Power Amplifier

$7,497.00 $9,746.10

Marantz Mm7055 5-channel Power Amplifier

$4,497.00 $5,711.19

Qsc Mp-a20v Multi-channel Amplifier (2-channel)

$3,405.00 $4,324.35

Ashly Mx406 Six Channel Stereo Microphone Mixer

$3,597.00 $5,107.74

Onkyo A-9110 2-channel 100w Integrated Amplifier

$1,047.00 $1,507.68

Products You May Like

Canon X25 Black Toner Cartridge

$303.27 $397.28

E-image Mh22 Motus 100mm Pro Fluid Head

$11,097.00 $15,979.68

Lulzbot Taz Pro/workhorse Abs+ Enclosure

$1,049.97 $1,574.95

Yamaha Seascooters Jetpod Pro Seascooter

$2,364.00 $3,356.88

Nila Elc-rjm-ip Cat 5 Cable Connector

$81.00 $124.74

Vixen Optics Extension Tube R200ss

$20.97 $27.05

Atlasied Atlas 221-18 Welded Rack (21 Ru)

$2,075.97 $2,781.80