Keep your servers, routers, switches, and other business-critical applications running during a power outage with the SMX3000LVNC Smart-UPS X 3000VA Rack/Tower with Network Card from APC. Capable of up to 2700W of power output, the SMX3000LVNC comes equipped with six NEMA 5-15R outlets, one NEMA L5-20R outlet, and three NEMA 5-20R outlets.

With a three-hour recharge time, the SMX3000LVNC comes with audible alarms to warn you of changing power conditions. The cold start-capable UPS also boasts a pre-installed network card, hot-swappable batteries, and a $150000 lifetime equipment protection policy.

Output: 2700W / 3000VA    Input: 120V    6 x NEMA 5-15R Outlets    1 x NEMA L5-20R Outlet    3 x NEMA 5-20R Outlets    Recharge Time: 3 Hours    Pre-Installed Network Card    Audible Alarms    Cold-Start/Hot-Swappable Batteries    $150000 Equipment Protection Policy

Key Specs
Total Outlets6x NEMA 5-15R
1x NEMA L5-30R
3x NEMA 5-20R
Plug TypeNEMA L5-30P
Surge Protection 540 Joules
Maximum Wattage2700 W
General
Total Outlets6x NEMA 5-15R
1x NEMA L5-30R
3x NEMA 5-20R
Protected Outlets6x NEMA 5-15R (Battery and Surge)
1x NEMA L5-30R (Battery and Surge)
3x NEMA 5-20R (Battery and Surge)
Plug TypeNEMA L5-30P
SmartSlot Interface1
Communications I/OSerial via RJ45
USB via USB-B
Emergency Power Off (EPO) SupportYes
TopologyLine Interactive
Transfer Time2 to 8 ms
Power
Surge Protection 540 Joules
Maximum Current15 A
Maximum Wattage2700 W
Nominal Input Voltage120 VAC
Input Voltage Range70 to 153 VAC
Input Frequency50/60 Hz ± 3 Hz (Auto Sensing)
Nominal Output Voltage120 VAC
Output Voltage Range100 to 127 VAC
Output Frequency50/60 Hz ± 3 Hz
Voltage Distortion<5%
Load Capacity3000 VA
Thermal Dissipation276 BTU/Hour
WaveformSine Wave
Battery
ChemistryLead-Acid
Recharge Time3 Hours
User ReplaceableYes
Replacement BatterySURTA2000RMXL2U
Hot-Swap SupportYes
Environmental
Operating Temperature32 to 72°F / 0 to 40°C
Operating Humidity0 to 95%
Storage Temperature5 to 104°F / -15 to 40°C
Storage Humidity0 to 95%
Storage Altitude49,212' / 15,000 m
Noise Level55 dBA
CertificationsBSMI, CSA, FCC, REACH, RoHS, TUV, UL, VCCI
Physical
Cable Length8' / 2.44 m
Rackmount Size4 RU (with Included Hardware)
Dimensions (W x H x D)19 x 17 x 7" / 48.26 x 43.18 x 17.78 cm
Weight85 lb / 38.56 kg
Packaging Info
Package Weight101 lb
Box Dimensions (LxWxH)25 x 23 x 13.3"

Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.

Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.

Enables communications with SMX, SMT, SRT, and SURTD Smart-UPS models using historical APC proprietary USB usages.

Provides notification of changing utility power and UPS power conditions.

UPS recognizes when external battery packs are attached and automatically adjusts runtime.

Automatically starts up the connected equipment upon the return of utility power.

Periodic battery self-test helps to ensure early detection of a battery that needs to be replaced.

Provides early-warning fault analysis on batteries enabling timely preventive maintenance.

Helps to eliminate voltage fluctuations as a source of AV signal degradation and component power-supply stress.

Provides temporary battery power when the utility power is out.

Warns when a battery is not available to provide backup power.

Provides actual kilowatt hours of usage for energy conscious users.

Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection.

Reduces or eliminates bulky transformers resulting in lighter units for ease of handling.

Reduces utility costs, generates less heat.

Helps to ensure clean, uninterrupted power to protected equipment while batteries are being replaced.

Maximizes battery performance, life, and reliability through intelligent, precision charging.

Designed to provide clear and accurate information in multiple languages with the ability to configure the UPS locally. Equipped with easy-to-use navigation keys.

Turn off select outlet groups in a pre-determined sequence to shed less critical equipment and conserve runtime.

Multiple outlet groups that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.

Provides proactive notifications of changing power or unit conditions and provides the user the ability to remotely control PMU functions.

Turn on/off, reboot, or shut down select outlet groups to save dispatching technicians to remote locations.

Safeguards unit from damage by automatically turning it off in the event of a short circuit or overload.

Provides early-warning fault analysis ensuring proactive component replacement.

Dynamically provides the month and year when battery replacement is recommended.

Provides for remote management and control of the UPS over a network out of the box.

Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.

Protects the initial investment in the UPS when migrating from tower to rack-mount environment.

Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

Allows additional run time to be quickly added as needed.

Customize network shutdown and reboot sequence of connected servers and UPSs.

Use any Home Automation network to monitor and control the S20 through its RS-232 serial port.

Enables centralized management via StruxureWare Data Center Expert.

Prolongs battery life by regulating the charge voltage according to battery temperature.

Provides management of the UPS via a USB port.

Increases availability by allowing a trained user to perform upgrades and replacements of the batteries, which helps to reduce Mean Time to Repair (MTTR).

Enables a quick recovery from overload events.

Helps to protect connected loads from surges, spikes, lightning, and other power disturbances.

Quickly understand unit and power status with visual indicators.

Related Questions and Answers

Q: 1. What is the run time at 50% load?

A: Run time at half load is about 9 minutes.

Q: 2. Is a low profile bracket included in the box?

A: Yes, this model comes with the low profile bracket, as pictured.

Q: 3. Will this work with Really Right Stuff plates?

A: Yes, the Novoflex Castel-XQ II Macro Focusing Rack is compatible with Really Right Stuff plates.

Q: 4. Will this support Windows 10?

A: Yes, it's just a UPS (nothing to do with OS's), you can use it with or without management software.

Q: 5. Will this work with all novoflex bellows systems?

A: Yes. The “Arca-type” bottom on all NOVOFLEX Macro Bellows fit any Q receptor in the NOVOFLEX line. As such, the NOVOFLEX Castel-XQ II Macro Focusing Rack would be compatible for use with all NOVOFLEX bellows systems.

Q: 6. I have a Arca Swiss Flip-Lock on my tripod, will this work with the Castel-XQ mounting system?

A: Yes.

Q: 7. Can this hold the seamless once the roll has been used and rerolled?

A: Yes, the following system will hold paper up to 4" holder diameter.

Q: 8. How long can it power a router and modem for if the power goes out?

A: This unit is rated for a full load runtime of 3 minutes and a half load runtime of 9 minutes. It would depend on the power draw of the items you had attached to the UPS.

Q: 9. What are the benefits of having a UPS with pure sine wave as opposed to a UPS with a stepped approximation to sine wave?

A: For most devices simulated sine wave is adequate. However, if you are backing up a device with an Active PFC (power factor correction) supply they require pure sine wave to operate correctly. Active PFC supplies are considerably more efficient than standard power supplies but need a clean input.

Q: 10. Does this unit have a release to quickly position the rail anywhere and then make macro adjustments? does the rail move using the two blue knobs on the bottom plate?

A: The bottom stage is geared directly and has no clutch to disengage the drive. The top stage locks and slides, but has no geared movement.

There are no reviews for this product.

Write a review

Note: HTML is not translated!
    Bad           Good
Captcha

Top Bestselling Products

Apc Ups Network Management Card 3

$1,037.97 $1,401.26

Apc Smart-ups Battery Backup With Network Card

$5,547.00 $7,821.27

Cyberpower Ol1000rtxl2un Smart App Online Ups

$3,239.85 $4,470.99

Cyberpower Ol1500rtxl2un Smart App Online Ups

$3,989.85 $6,383.76

Cyberpower Ol2200rtxl2un Smart App Online Ups

$5,414.85 $6,606.12

Apc Smart-ups Battery Backup With Network Card

$5,714.97 $7,600.91

Apc Smart-ups Battery Backup With Network Card

$5,397.00 $8,257.41

Feiyu Vlog Pocket 2 Handheld Gimbal

$269.64 $401.76

Products You May Like

Cougar Qbx Mini-tower Case (black)

$209.97 $323.35

Fujifilm Np-w126s Li-ion Battery Pack

$179.85 $239.20

Triad-orbit Tds Desktop Tripod Stand

$299.97 $431.96

Profoto Clic Magnum Reflector

$567.00 $691.74

Decksaver Allen & Heath Xone:96 Cover

$269.97 $375.26