Lowell Manufacturing Acr-seq6-2009 Rackmount Power Sequencer
- Product Code: ga192490
-
Power on your devices in sequence with the Lowell Manufacturing ACR-SEQ6-2009 Rackmount Power Sequencer. It features eight rear outlets (six of which are switched), plus two additional unswitched outlets on the rear, and one on the front. The time between each step in the sequence can be adjusted with a screwdriver from 0.5 to 10 seconds.
6 Switched 3-Prong Outlets on Rear 2 Unswitched 3-Prong Outlets on Rear Front Unswitched 3-Prong Outlet Front Circuit Breaker Reset Button EMI and RFI Filtering Alarm System and Remote Switch Inputs Remote Power Control Output
Key Specs | |
---|---|
Metering | None |
Battery Backup | No |
Outlets | 6x NEMA 5-15R (Rear Panel, Switched) 2x NEMA 5-15R (Rear Panel, Unswitched) 1x NEMA 5-15R (Front Panel, Unswitched) |
Additional I/O | 2x Block 4-Pin (Remote) 1x Block 4-Pin (Remote) |
Parameters | |
Type | Sequencer |
Amp Rating | 20 A |
Number of Circuits | Not Specified by Manufacturer |
Metering | None |
Battery Backup | No |
Typical Backup Runtime | Not Specified by Manufacturer |
Integrated Lamps | None |
Connections | |
Outlets | 6x NEMA 5-15R (Rear Panel, Switched) 2x NEMA 5-15R (Rear Panel, Unswitched) 1x NEMA 5-15R (Front Panel, Unswitched) |
Wall Plug Type | NEMA L5-20P |
AC Power I/O | Hardwired |
Lamp I/O | No |
Additional I/O | 2x Block 4-Pin (Remote) 1x Block 4-Pin (Remote) |
Wireless | No |
Electrical | |
AC Input Power | 120 VAC, 60 Hz (20 A) |
DC Output Power | Not Specified by Manufacturer |
Output Current | 15 A |
Load Capacity | Not Specified by Manufacturer |
Sequencing Delay | Adjustable, 0.5 Seconds to 10 Seconds |
Protection & Conditioning | |
Protection Types & Modes | EMI Filter |
Circuit Breaker | Yes, at 20 A with Push-Button Reset |
EMI/RFI Noise Filtration | 19 dB (500 kHz) 42 dB (30 MHz) |
Physical | |
Rackmount Size | 1 RU |
Cable Length | 9' / 2.7 m |
Certifications | ETL |
Material of Construction | Steel |
Dimensions | 19 x 9 x 1.75" / 48.3 x 22.9 x 4.45 cm |
Weight | 11 lb / 5 kg |
A front rocker switch with momentary contacts (normally open SPST) plus rear barrier strip termination blocks for momentary (normally open) remote switches are onboard. The switch initializes the delayed startup sequence, activating the switched outlets in four steps, plus any remote power controls (RPCs) connected to the rear terminal block as steps five and six. A green LED flashes while the unit is powering up and holds steady when the cycle is complete. The switch also initializes the delayed shutdown sequence, deactivating RPCs and outlets in reverse order. A red LED flashes while the unit is powering down and holds steady when the cycle is complete. The delay between steps can be adjusted with a screwdriver (0.5 to 10 seconds).
The plug-in barrier-strip terminal-block inputs on the rear of the panel allow external controls to activate and deactivate the switched outlets. The terminal block output allows this panel to control remote RPC units.
- Left Terminal Block: Input from alarm system—lock on, lock off, and switch lock for an alarm system or master control panel.
- Center Terminal Block: Output to Remote Power Control (RPC)—external RPC series devices can be controlled when connected to the center terminal block. The connected RPCs would activate/deactivate as steps 5 and 6.
- Right Terminal Block: Input from Remote Switch—connect a remote switch with momentary closure.
- Nine total marked NEMA outlets—one unswitched on the front, two unswitched on the rear, six switched on the rear
- 20A circuit breaker.
- Rear termination blocks accommodate remote switches, external triggers, and an alarm system interface for use where mandated by fire code.
- The compact steel chassis with black powder epoxy finish is designed to occupy minimal rack space.
Related Questions and Answers
Q: 1. Will it work with the E-M1 Mark iii?
A: YES, see page 24 of E-M1 Mark III manual https://learnandsupport.getolympus.com/sites/default/files/media/files/2020/02/E-M1Mk3_ENU_00.pdf
Q: 2. Can I use it to charge batteries?
A: This device is not a charger.
Q: 3. Is a battery included?
A: No, this item does not include batteries.
Q: 4. Does this work with 26V batteries?
A: The SmallHD V-Mount Power Kit is not compatible with 26V batteries. A 26V compatible kit would be the SmallHD 14V/26V Dual Battery Bracket (V-Mount), BH #SMPWRPB4K2VM.
Q: 5. Hi! Am I able to power my Dracast LED1000 with this accessory?
A: Unfortunately, the POWER POD is really made for less power hungry devices such as small cameras and their accessories. While you could get a cable and connect the POWER POD Quad LP-E6 to the LED1000, we would recommend against it. The POWER PODs maximum watt hour rating of 53Wh would last a little more than half as much as a 98wh V-mount or Gold Mount battery. This is the reason the Dracast LED1000 is designed to work with V-mount and Gold Mount batteries. One example of such a battery is the Switronix XP-L90A 14.8 VDC Lithium Ion Brick Battery B&H # SWXPL90A.
Q: 6. Can this item be used with others laptop as Asus etc.?
A: There is no way of knowing the shape and layout of your Asus optical drive bracket which is what this device replaces. It's possible, but you'd have to open up your Asus and have a look. the data and power cable connections will be the same but the shape, size, and mounting points of the Asus bracket may differ. You may want to use an external drive if your skills and tool set for working on laptops is limited.
Q: 7. is there a 3.5mm or 1/4" jack for radio slaves/pocket wizards?
A: The following system has its own internal receiver please review the following item Godox XProC TTL Wireless Flash Trigger for Canon Cameras BH #GOXPROC • MFR #XPROC https://bhpho.to/3KmoLBL
Q: 8. Are the cables on the heads detachable? Or are they permanently attached to the heads?
A: The heads can be detached from the packs but the cables are permanently attached to the heads.
Q: 9. each flash can fire with 2400w each when plugged together ?
A: The total power of the P2400 is 2400 watt/sec, but you would get that amount of power when a single head is connected. Two connected heads would split the power in half.
Q: 10. Can I use this divider kit for the 1606 Pelican air?
A: Unfortunately, this Trekpak Divider Kit is not compatible with the Pelican 1606.
Top Bestselling Products
Tilta D-tap To 4-pin Lemo-type Power Cable For Red Dsmc2 Cameras
$141.00 $215.73
Manfrotto Q5 L Bracket
$689.64 $993.08
Intrepid Camera 8 X 10 View Camera (green)
$1,848.00 $2,328.48
Tilta Rear Top Plate For Red V-raptor
$237.00 $334.17
Ikelite 5509.35 Zoom/focus Gear
$75.00 $90.75
Tamron 8mm Fixed Focal Lens (c-mount)
$899.85 $1,286.79
Venus Optics Laowa 7.5mm T2.1 Cine Lens (mft, Feet)
$1,797.00 $2,785.35
Tilta Bottom Mounting Plate For Red V-raptor Camera Cage
$45.00 $58.50
Kaiser 90mm Push-on Lens Cap
$57.00 $84.36
Explorer Photo & Video Ex-26 Quick Release Plate
$44.97 $71.05
8sinn Wooden Grip With Arri Rosette (right Side)
$417.00 $638.01
Toyo-view 180-886 Aluminum Case
$2,306.85 $3,644.82
Hahnemuhle Canvas Metallic (24" X 39' Roll)
$794.10 $1,135.56
Products You May Like
Heliopan Bay 6 Rg 1000 Infrared Filter
$809.85 $1,117.59
Olight I5r Eos Edc Flashlight (black)
$107.85 $134.81
Winsted W6471 Single Lcd Pole Mount
$1,009.50 $1,312.35
Portabrace Custom Audio Recorder Case For Tascam Portacapture X8
$297.18 $419.02
Power Production Storyboard Quick (10-19 Licenses)
$577.50 $785.40
Camplex 12-channel Fiber Optic Tactical Cable Reel With St Connectors (1250')
$8,671.47 $11,706.48
7artisans Photoelectric Variable Nd Filter (62mm, 8-stop)
$183.00 $239.73
Hpe Networking Uxi G6c Sensor (lte)
$4,197.00 $5,498.07
Apexel 10x25 Porro Binoculars
$82.50 $119.62
Fix It Sticks Hook-and-loop Patch
$18.00 $25.92
Schneider Converter Lens Bracket
$188.85 $262.50
Canon Pfi-007y Yellow Ink Tank (90ml)
$195.00 $274.95